Phoenix FL SWITCH NSF 16TX
- Ethernet Switch
- 16 TP RJ45 ports
- Automatic detection of data transmission speed of 10 or 100 Mbps (RJ45)
- Autocrossing function































| Interface 1 | Ethernet (RJ45) |
|---|---|
| No. of ports | 16 (RJ45 ports) |
| Connection method | RJ45 |
| Note on connection method | Auto negotiation and autocrossing |
| Transmission physics | Ethernet in RJ45 twisted pair |
| Transmission speed | 10/100 MBit/s |
| Transmission length | 100 m (per segment) |
| Signal LEDs | Data receive, link status |
| Interface 4 | Potential-free signaling contact |
| Connection method | Plug-in/screw connection via COMBICON |

| Basic functions | Unmanaged switch / autonegotiation, complies with IEEE 802.3, store and forward switching mode |
|---|---|
| Status and diagnostic indicators | LEDs: US1, US2 (redundant voltage supply), link and activity per port |

| Cascading depth | Network, linear, and star structure: any |
|---|---|
| Maximum conductor length ((twisted pair) | 100 m |

| Supply voltage | 24 V DC |
|---|---|
| Residual ripple | 3.6 VPP (within the permitted voltage range) |
| Supply voltage range | 18.5 V DC ... 30.2 V DC |
| Typical current consumption | typ. 300 mA |
| Max. current consumption | typ. |

| Width | 205 mm |
|---|---|
| Height | 94.3 mm |
| Depth | 30 mm |
| Mounting type | DIN rail |
| Type AX | Block design |
| Weight | 380 g |
| Degree of protection | IP20 |
| Ambient temperature (operation) | 0 °C ... 55 °C |
| Ambient temperature (storage/transport) | -20 °C ... 70 °C |
| Permissible humidity (operation) | 5 % ... 95 % (no condensation) |
| Permissible humidity (storage/transport) | 5 % ... 95 % (no condensation) |
| Air pressure (operation) | 86 kPa ... 108 kPa (up to 1500 m above mean sea level) |
| Air pressure (storage/transport) | 66 kPa ... 108 kPa (up to 3500 m above mean sea level) |
| Housing material | Aluminum |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2:2005 |

| Developed in acc. with standard | IEC 61000-6.2 |
|---|---|
| Test standard | IEC 61000-4-2 (ESD) |
| Test result | Criterion B |
| Test standard | IEC 61000-4-3 (immunity to radiated interference) |
| Test result | Criterion A |
| Test standard | IEC 61000-4-4 (burst) |
| Test result | Criterion B |
| Test standard | IEC 61000-4-5 (surge) |
| Test result | Criterion B |
| Test standard | IEC 61000-4-6 (immunity to conducted interference) |
| Test result | Criterion A |
| Test standard | IEC 61000-4-8 (immunity to magnetic fields) |
| Test result | Criterion A |
| Test standard | EN 55022 (emitted interference) |
| Test result | Criterion A |